Good price  online

products details

Home > Products >
Electric Busway
>
SK-LINE-M Series Intensive Busway For Industrial

SK-LINE-M Series Intensive Busway For Industrial

Brand Name: ohory electric
Model Number: SK-LINE-M/4P,SK-LINE-M/5P
MOQ: 1000
Payment Terms: L/C,D/A,D/P,T/T,Western Union,
Detail Information
Place of Origin:
Guangdong, China
Certification:
China Energy Conservation Product Certification
Executive Standards:
GB/T7251.6-2015,IEC61439-6:2012、EN61439-6:2012
Material:
Cu+Ag≥99.97%
Housing:
6063-T5 Aluminum Magnesiun Alloy
Unit Length:
Any Choice Between 0.5~0.6 Meters
Protection Grade:
IP54,IP55,IP65,IP66
Highlight:

SK-LINE-M Intensive Busway

,

Industrial Busway IP66

,

IEC 61439-6 Busbar Trunking

Product Description

SK-LINE-M Series Intensive Busway for Industrial Power Distribution

In short: The SK-LINE-M Series is a heavy duty intensive busway for industrial power distribution, built to GB/T 7251.6-2015 and IEC 61439-6:2012 with 99.97% oxygen free copper conductors and a 6063-T5 aluminum magnesium alloy housing.

Quick Facts

ItemDetail
Product seriesSK-LINE-M intensive busway
Executive standardsGB/T 7251.6-2015, IEC 61439-6:2012, EN 61439-6:2012
Conductor materialCu + Ag ≥ 99.97%
Housing material6063-T5 aluminum magnesium alloy
Unit lengthCustomizable 0.5 - 0.6 m
Protection gradeIP54 / IP55 / IP65 / IP66

Key Features

  • Intensive construction — Short unit sections and close conductor spacing keep voltage drop low over long industrial runs.
  • High purity copper — Cu + Ag ≥ 99.97% conductors hold stable joint resistance under continuous heavy load.
  • Aluminum magnesium housing — The 6063-T5 alloy shell gives stiffness without the weight of a steel enclosure.
  • Four protection grades — IP54 through IP66 let one design cover indoor plant rooms and washdown areas.

Technical Specifications

ParameterSpecification
Executive standardsGB/T 7251.6-2015, IEC 61439-6:2012, EN 61439-6:2012
ConductorCu + Ag ≥ 99.97%
Housing6063-T5 aluminum magnesium alloy
Unit length0.5 - 0.6 m, customizable
Protection gradeIP54 / IP55 / IP65 / IP66

Typical Applications

  • Factory main distribution and workshop feeders
  • Heavy industry production lines and smelting plants
  • Large warehouse and logistics hubs

Frequently Asked Questions

Q: What does intensive busway mean?

A: Intensive busway uses short, closely packed sections so the conductor runs nearly straight, which lowers impedance and voltage drop compared with standard sandwich busway.

Q: Can the unit length be customized?

A: Yes. Sections are produced between 0.5 and 0.6 meters to match your route and are adjustable at order stage.

Q: Which standard is it tested to?

A: The series is built and tested to GB/T 7251.6-2015, IEC 61439-6:2012 and EN 61439-6:2012.

Ordering and Support

Ohory supplies this product with factory tested sections, coordinated accessories and project documentation. Send your single line diagram, route drawing and load schedule and our engineers will confirm the configuration, section lengths and delivery schedule.

Good price  online

Products Details

Home > Products >
Electric Busway
>
SK-LINE-M Series Intensive Busway For Industrial

SK-LINE-M Series Intensive Busway For Industrial

Brand Name: ohory electric
Model Number: SK-LINE-M/4P,SK-LINE-M/5P
MOQ: 1000
Payment Terms: L/C,D/A,D/P,T/T,Western Union,
Detail Information
Place of Origin:
Guangdong, China
Brand Name:
ohory electric
Certification:
China Energy Conservation Product Certification
Model Number:
SK-LINE-M/4P,SK-LINE-M/5P
Executive Standards:
GB/T7251.6-2015,IEC61439-6:2012、EN61439-6:2012
Material:
Cu+Ag≥99.97%
Housing:
6063-T5 Aluminum Magnesiun Alloy
Unit Length:
Any Choice Between 0.5~0.6 Meters
Protection Grade:
IP54,IP55,IP65,IP66
Minimum Order Quantity:
1000
Delivery Time:
5-8 work day
Payment Terms:
L/C,D/A,D/P,T/T,Western Union,
Highlight:

SK-LINE-M Intensive Busway

,

Industrial Busway IP66

,

IEC 61439-6 Busbar Trunking

Product Description

SK-LINE-M Series Intensive Busway for Industrial Power Distribution

In short: The SK-LINE-M Series is a heavy duty intensive busway for industrial power distribution, built to GB/T 7251.6-2015 and IEC 61439-6:2012 with 99.97% oxygen free copper conductors and a 6063-T5 aluminum magnesium alloy housing.

Quick Facts

ItemDetail
Product seriesSK-LINE-M intensive busway
Executive standardsGB/T 7251.6-2015, IEC 61439-6:2012, EN 61439-6:2012
Conductor materialCu + Ag ≥ 99.97%
Housing material6063-T5 aluminum magnesium alloy
Unit lengthCustomizable 0.5 - 0.6 m
Protection gradeIP54 / IP55 / IP65 / IP66

Key Features

  • Intensive construction — Short unit sections and close conductor spacing keep voltage drop low over long industrial runs.
  • High purity copper — Cu + Ag ≥ 99.97% conductors hold stable joint resistance under continuous heavy load.
  • Aluminum magnesium housing — The 6063-T5 alloy shell gives stiffness without the weight of a steel enclosure.
  • Four protection grades — IP54 through IP66 let one design cover indoor plant rooms and washdown areas.

Technical Specifications

ParameterSpecification
Executive standardsGB/T 7251.6-2015, IEC 61439-6:2012, EN 61439-6:2012
ConductorCu + Ag ≥ 99.97%
Housing6063-T5 aluminum magnesium alloy
Unit length0.5 - 0.6 m, customizable
Protection gradeIP54 / IP55 / IP65 / IP66

Typical Applications

  • Factory main distribution and workshop feeders
  • Heavy industry production lines and smelting plants
  • Large warehouse and logistics hubs

Frequently Asked Questions

Q: What does intensive busway mean?

A: Intensive busway uses short, closely packed sections so the conductor runs nearly straight, which lowers impedance and voltage drop compared with standard sandwich busway.

Q: Can the unit length be customized?

A: Yes. Sections are produced between 0.5 and 0.6 meters to match your route and are adjustable at order stage.

Q: Which standard is it tested to?

A: The series is built and tested to GB/T 7251.6-2015, IEC 61439-6:2012 and EN 61439-6:2012.

Ordering and Support

Ohory supplies this product with factory tested sections, coordinated accessories and project documentation. Send your single line diagram, route drawing and load schedule and our engineers will confirm the configuration, section lengths and delivery schedule.