| Brand Name: | ohory |
| Model Number: | OH-DCB-ARC |
| MOQ: | 10 Meters |
| Price: | USD 140-360 / Meter |
| Packaging Details: | Plywood case with joint covers braced internally, arc flash label set and test report folder included |
| Payment Terms: | T/T, L/C at sight |
The OH-DCB-ARC series is for runs where incident energy at the main distribution level is high enough to drive the arc flash boundary beyond the available working space. Pressure relief paths, reinforced joint covers and front only access are combined with IEC 61641 testing at 50kA so the containment claim is supported by a test report rather than a design note.
| Rated Current | 1250A - 6300A |
|---|---|
| Internal Arc Classification | IEC 61641, tested at rated current and 50kA fault |
| Pressure Relief | Rear and top relief flaps with mesh flame arrestor |
| Enclosure Strength | Reinforced 3.0mm steel at joint zones |
| Access Classification | Type A front access, Type B option |
| Rated Insulation Voltage | 1000V AC |
| Rated Working Voltage | 690V AC |
| Arc Test Duration | 0.3s and 1.0s sequences |
| Surface Temperature | No ignition of indicator cloth outside enclosure |
| Protection Degree | IP54 indoor |
| Test Standard | IEC 61641 / IEC 61439-6 / UL 857 |
Internal arc testing to IEC 61641 covers joint, tap off and end positions with indicator cloth verification. Incident energy calculations and arc flash labels are provided for the electrical safety study.
Provide transformer fault level, expected incident energy, access side requirement and run layout including joint positions.
| Brand Name: | ohory |
| Model Number: | OH-DCB-ARC |
| MOQ: | 10 Meters |
| Price: | USD 140-360 / Meter |
| Packaging Details: | Plywood case with joint covers braced internally, arc flash label set and test report folder included |
| Payment Terms: | T/T, L/C at sight |
The OH-DCB-ARC series is for runs where incident energy at the main distribution level is high enough to drive the arc flash boundary beyond the available working space. Pressure relief paths, reinforced joint covers and front only access are combined with IEC 61641 testing at 50kA so the containment claim is supported by a test report rather than a design note.
| Rated Current | 1250A - 6300A |
|---|---|
| Internal Arc Classification | IEC 61641, tested at rated current and 50kA fault |
| Pressure Relief | Rear and top relief flaps with mesh flame arrestor |
| Enclosure Strength | Reinforced 3.0mm steel at joint zones |
| Access Classification | Type A front access, Type B option |
| Rated Insulation Voltage | 1000V AC |
| Rated Working Voltage | 690V AC |
| Arc Test Duration | 0.3s and 1.0s sequences |
| Surface Temperature | No ignition of indicator cloth outside enclosure |
| Protection Degree | IP54 indoor |
| Test Standard | IEC 61641 / IEC 61439-6 / UL 857 |
Internal arc testing to IEC 61641 covers joint, tap off and end positions with indicator cloth verification. Incident energy calculations and arc flash labels are provided for the electrical safety study.
Provide transformer fault level, expected incident energy, access side requirement and run layout including joint positions.