| Brand Name: | ohory |
| Model Number: | OH-DCB-ICW100 |
| MOQ: | 10 Meters |
| Price: | USD 95-260 / Meter |
| Packaging Details: | Seaworthy plywood case with moisture barrier film, joint kits and end covers packed separately |
| Payment Terms: | T/T, L/C at sight, Western Union |
The OH-DCB-ICW100 series is built for AI data centers where available fault current at the main distribution board exceeds the withstand rating of conventional busway. A verified 100kA conditional short-circuit withstand and a 220kA peak withstand let the run hold selectivity with upstream breakers without oversizing the power train, while the integral earth conductor keeps fault return paths continuous through every joint.
| Rated Current Range | 1250A - 6300A |
|---|---|
| Conditional Short-Circuit Withstand (Icw) | 100kA / 1s |
| Peak Withstand Current (Ipk) | 220kA |
| Rated Insulation Voltage | 1000V AC |
| Rated Working Voltage | 690V AC |
| Rated Frequency | 50 / 60 Hz |
| Phase Conductor | Electrolytic copper 99.95 percent, silver plated joints |
| Integral Earth Conductor | 50 percent of phase cross section, full length continuity |
| Conductor Insulation | Epoxy powder coated, Class F 155 C |
| Temperature Rise | Less than or equal to 30K at rated current |
| Dielectric Withstand | 3.5kV 1min power frequency |
| Protection Degree | IP54 indoor, IP68 option |
| Test Standard | IEC 61439-6 / UL 857 / GB 7251.6 |
Each production batch undergoes power frequency dielectric tests, insulation resistance measurement and contact resistance verification. Type test reports covering short circuit withstand, temperature rise and fire performance are available for consultant submittals.
Please specify rated current, run length, number of tap off positions, protection degree, earth conductor requirement and the fault level from your coordination study.
| Brand Name: | ohory |
| Model Number: | OH-DCB-ICW100 |
| MOQ: | 10 Meters |
| Price: | USD 95-260 / Meter |
| Packaging Details: | Seaworthy plywood case with moisture barrier film, joint kits and end covers packed separately |
| Payment Terms: | T/T, L/C at sight, Western Union |
The OH-DCB-ICW100 series is built for AI data centers where available fault current at the main distribution board exceeds the withstand rating of conventional busway. A verified 100kA conditional short-circuit withstand and a 220kA peak withstand let the run hold selectivity with upstream breakers without oversizing the power train, while the integral earth conductor keeps fault return paths continuous through every joint.
| Rated Current Range | 1250A - 6300A |
|---|---|
| Conditional Short-Circuit Withstand (Icw) | 100kA / 1s |
| Peak Withstand Current (Ipk) | 220kA |
| Rated Insulation Voltage | 1000V AC |
| Rated Working Voltage | 690V AC |
| Rated Frequency | 50 / 60 Hz |
| Phase Conductor | Electrolytic copper 99.95 percent, silver plated joints |
| Integral Earth Conductor | 50 percent of phase cross section, full length continuity |
| Conductor Insulation | Epoxy powder coated, Class F 155 C |
| Temperature Rise | Less than or equal to 30K at rated current |
| Dielectric Withstand | 3.5kV 1min power frequency |
| Protection Degree | IP54 indoor, IP68 option |
| Test Standard | IEC 61439-6 / UL 857 / GB 7251.6 |
Each production batch undergoes power frequency dielectric tests, insulation resistance measurement and contact resistance verification. Type test reports covering short circuit withstand, temperature rise and fire performance are available for consultant submittals.
Please specify rated current, run length, number of tap off positions, protection degree, earth conductor requirement and the fault level from your coordination study.