| Brand Name: | ohory |
| Model Number: | OH-DCB-PFB |
| MOQ: | 1 Set |
| Price: | USD 120-310 / Meter |
| Packaging Details: | Containerized steel frame packing with section labels, joint kits and torque records in a document box |
| Payment Terms: | T/T 30 percent deposit, balance before shipment |
The OH-DCB-PFB series shifts fabrication from the site to the factory. Sections arrive cut, bent, terminated and labelled to the container layout within plus minus 2mm, so installation is bolted joints only. That removes cutting and drilling from the data hall and compresses assembly to about 30 days for a standard hall.
| Rated Current | 630A - 2500A |
|---|---|
| Delivery Format | Pre cut, pre bent and pre terminated sections |
| Section Length Tolerance | Plus minus 2mm, matched to container dimensions |
| Labels | Section, joint and torque labels pre applied to site layout |
| Site Assembly | Bolted joints only, no cutting or bending on site |
| Rated Insulation Voltage | 1000V AC |
| Rated Working Voltage | 690V AC |
| Factory Testing | Routine dielectric and continuity test per section |
| Assembly Time | Target 30 days for a standard hall, 2 shifts per day |
| Protection Degree | IP54 indoor, IP66 option |
| Test Standard | IEC 61439-6 / UL 857 |
Every section receives routine dielectric and continuity testing before crating, and records travel with the shipment. Factory dimensional reports confirm fit to the container drawing before dispatch.
Supply container or hall drawings, current rating, tap off positions, protection degree and required delivery date for each module.
| Brand Name: | ohory |
| Model Number: | OH-DCB-PFB |
| MOQ: | 1 Set |
| Price: | USD 120-310 / Meter |
| Packaging Details: | Containerized steel frame packing with section labels, joint kits and torque records in a document box |
| Payment Terms: | T/T 30 percent deposit, balance before shipment |
The OH-DCB-PFB series shifts fabrication from the site to the factory. Sections arrive cut, bent, terminated and labelled to the container layout within plus minus 2mm, so installation is bolted joints only. That removes cutting and drilling from the data hall and compresses assembly to about 30 days for a standard hall.
| Rated Current | 630A - 2500A |
|---|---|
| Delivery Format | Pre cut, pre bent and pre terminated sections |
| Section Length Tolerance | Plus minus 2mm, matched to container dimensions |
| Labels | Section, joint and torque labels pre applied to site layout |
| Site Assembly | Bolted joints only, no cutting or bending on site |
| Rated Insulation Voltage | 1000V AC |
| Rated Working Voltage | 690V AC |
| Factory Testing | Routine dielectric and continuity test per section |
| Assembly Time | Target 30 days for a standard hall, 2 shifts per day |
| Protection Degree | IP54 indoor, IP66 option |
| Test Standard | IEC 61439-6 / UL 857 |
Every section receives routine dielectric and continuity testing before crating, and records travel with the shipment. Factory dimensional reports confirm fit to the container drawing before dispatch.
Supply container or hall drawings, current rating, tap off positions, protection degree and required delivery date for each module.