| Brand Name: | ohory |
| Model Number: | OH-DCB-N200 |
| MOQ: | 10 Meters |
| Price: | USD 110-300 / Meter |
| Packaging Details: | Plywood case with neutral bar protection caps and joint kits packed separately |
| Payment Terms: | T/T, L/C at sight |
The OH-DCB-N200 series addresses a failure mode that standard busway ignores. Modern servers, GPUs and UPS inverters draw non linear current, and triplen harmonics add in the neutral instead of cancelling. With a neutral conductor rated at 200 percent of the phase section and a double lug neutral bar in every tap off, the run keeps neutral temperature rise within 30K at full harmonic load.
| Rated Current | 800A - 4000A phase, 1600A - 8000A neutral |
|---|---|
| Neutral Rating | 200 percent of phase cross section, full length |
| Harmonic Withstand | Designed for triplen harmonic content up to 100 percent |
| Rated Insulation Voltage | 1000V AC |
| Rated Working Voltage | 400 / 690V AC |
| Rated Frequency | 50 / 60 Hz |
| Conductor Material | Electrolytic copper, tin plated |
| Neutral Temperature Rise | Less than or equal to 30K at full harmonic load |
| Neutral Terminal | Double lug neutral bar in every tap off unit |
| Protection Degree | IP54 indoor, IP66 option |
| Test Standard | IEC 61439-6 / UL 857 |
Type tests include neutral conductor temperature rise under 100 percent triplen harmonic loading, short circuit withstand and dielectric verification. Harmonic loading reports are issued with each project submittal.
State phase current, harmonic spectrum from the load study, neutral rating required, tap off quantity and protection degree.
| Brand Name: | ohory |
| Model Number: | OH-DCB-N200 |
| MOQ: | 10 Meters |
| Price: | USD 110-300 / Meter |
| Packaging Details: | Plywood case with neutral bar protection caps and joint kits packed separately |
| Payment Terms: | T/T, L/C at sight |
The OH-DCB-N200 series addresses a failure mode that standard busway ignores. Modern servers, GPUs and UPS inverters draw non linear current, and triplen harmonics add in the neutral instead of cancelling. With a neutral conductor rated at 200 percent of the phase section and a double lug neutral bar in every tap off, the run keeps neutral temperature rise within 30K at full harmonic load.
| Rated Current | 800A - 4000A phase, 1600A - 8000A neutral |
|---|---|
| Neutral Rating | 200 percent of phase cross section, full length |
| Harmonic Withstand | Designed for triplen harmonic content up to 100 percent |
| Rated Insulation Voltage | 1000V AC |
| Rated Working Voltage | 400 / 690V AC |
| Rated Frequency | 50 / 60 Hz |
| Conductor Material | Electrolytic copper, tin plated |
| Neutral Temperature Rise | Less than or equal to 30K at full harmonic load |
| Neutral Terminal | Double lug neutral bar in every tap off unit |
| Protection Degree | IP54 indoor, IP66 option |
| Test Standard | IEC 61439-6 / UL 857 |
Type tests include neutral conductor temperature rise under 100 percent triplen harmonic loading, short circuit withstand and dielectric verification. Harmonic loading reports are issued with each project submittal.
State phase current, harmonic spectrum from the load study, neutral rating required, tap off quantity and protection degree.