Data Center Busway System
>
Rack Level Metered Tap Off Unit 16A-63A Per Outlet kWh Metering for AI Data Center Busway

Rack Level Metered Tap Off Unit 16A-63A Per Outlet kWh Metering for AI Data Center Busway

Brand Name: ohory
Model Number: OH-DCB-MTO
MOQ: 20 Pieces
Price: USD 85-210 / Piece
Packaging Details: Individual carton with calibration certificate, register map card and connector protection cap
Payment Terms: T/T, L/C at sight, Western Union
Detail Information
Place of Origin:
Guangdong, China
Certification:
ISO 9001 / IEC 61439-6 / IEC 62053-21 / CNAS
Rated Current:
16A / 32A / 63A Per Outlet
Outlets Per Unit:
3, 6 Or 12 Outlet Configurations
Metering Accuracy:
Class 1 Per Outlet, KWh And Instantaneous KW
Metering Output:
Modbus RTU RS485, SNMP Gateway Option
Display:
Local LCD Per Outlet, Cumulative And Resettable Registers
Voltage:
220 / 380V AC, Single And Three Phase Outlets
Connection:
Tool Free Plug In To Busway, No Interruption To Adjacent Units
Enclosure:
Flame Retardant PC And Steel, IP20
Metering Standard:
IEC 62053-21 Class 1
Test Standard:
IEC 61439-6 / IEC 62053-21
Supply Ability:
5000 Pieces per Month
Highlight:

Metered Tap Off Unit 16A-63A

,

Per Outlet kWh Metering Tap Off

,

Busway Tap Off Unit for Data Center

Product Description

Rack Level Metered Tap Off Unit with Per Outlet kWh Metering

The OH-DCB-MTO series moves metering to the point of use. Every outlet carries a class 1 kWh meter with a local display and Modbus output, so rack level billing and power trend data arrive without a separate meter panel or current transformers. The tool free plug in connection lets units be added during live operation.

Key Features

  • Per Outlet kWh Metering: Class 1 accuracy on every outlet so rack level billing needs no separate meter panel
  • Tool Free Plug In: Unit engages the busway without tools and without interrupting adjacent tap offs
  • Modbus RTU Output: Register map documented for BMS and DCIM integration out of the box
  • Local LCD Registers: Cumulative and resettable registers readable at the rack during fit out and audit
  • Mixed Outlet Configurations: C13, C19 and three phase outlets combined in one unit footprint

Applications

  • Colocation halls billing power per rack
  • AI data center GPU racks with per tenant power tracking
  • Facilities integrating rack power data into DCIM or BMS
  • Retrofit metering where panel level meters are not available

Technical Specifications

Rated Current16A / 32A / 63A per outlet
Outlets per Unit3, 6 or 12 outlet configurations
Metering AccuracyClass 1 per outlet, kWh and instantaneous kW
Metering OutputModbus RTU RS485, SNMP gateway option
DisplayLocal LCD per outlet, cumulative and resettable registers
Voltage220 / 380V AC, single and three phase outlets
ConnectionTool free plug in to busway, no interruption to adjacent units
EnclosureFlame retardant PC and steel, IP20
Metering StandardIEC 62053-21 class 1
Test StandardIEC 61439-6 / IEC 62053-21

Compliance and Testing

Metering accuracy is verified against IEC 62053-21 class 1 reference equipment, and each unit receives a factory calibration certificate with a documented Modbus register map.

Ordering Information

Specify outlet configuration, current per outlet, single or three phase arrangement, communication protocol and label wording for tenant identification.

Related Products

Good price  online

Products Details

Home > Products >
Data Center Busway System
>
Rack Level Metered Tap Off Unit 16A-63A Per Outlet kWh Metering for AI Data Center Busway

Rack Level Metered Tap Off Unit 16A-63A Per Outlet kWh Metering for AI Data Center Busway

Brand Name: ohory
Model Number: OH-DCB-MTO
MOQ: 20 Pieces
Price: USD 85-210 / Piece
Packaging Details: Individual carton with calibration certificate, register map card and connector protection cap
Payment Terms: T/T, L/C at sight, Western Union
Detail Information
Place of Origin:
Guangdong, China
Brand Name:
ohory
Certification:
ISO 9001 / IEC 61439-6 / IEC 62053-21 / CNAS
Model Number:
OH-DCB-MTO
Rated Current:
16A / 32A / 63A Per Outlet
Outlets Per Unit:
3, 6 Or 12 Outlet Configurations
Metering Accuracy:
Class 1 Per Outlet, KWh And Instantaneous KW
Metering Output:
Modbus RTU RS485, SNMP Gateway Option
Display:
Local LCD Per Outlet, Cumulative And Resettable Registers
Voltage:
220 / 380V AC, Single And Three Phase Outlets
Connection:
Tool Free Plug In To Busway, No Interruption To Adjacent Units
Enclosure:
Flame Retardant PC And Steel, IP20
Metering Standard:
IEC 62053-21 Class 1
Test Standard:
IEC 61439-6 / IEC 62053-21
Minimum Order Quantity:
20 Pieces
Price:
USD 85-210 / Piece
Packaging Details:
Individual carton with calibration certificate, register map card and connector protection cap
Delivery Time:
12-20 working days after order confirmation
Payment Terms:
T/T, L/C at sight, Western Union
Supply Ability:
5000 Pieces per Month
Highlight:

Metered Tap Off Unit 16A-63A

,

Per Outlet kWh Metering Tap Off

,

Busway Tap Off Unit for Data Center

Product Description

Rack Level Metered Tap Off Unit with Per Outlet kWh Metering

The OH-DCB-MTO series moves metering to the point of use. Every outlet carries a class 1 kWh meter with a local display and Modbus output, so rack level billing and power trend data arrive without a separate meter panel or current transformers. The tool free plug in connection lets units be added during live operation.

Key Features

  • Per Outlet kWh Metering: Class 1 accuracy on every outlet so rack level billing needs no separate meter panel
  • Tool Free Plug In: Unit engages the busway without tools and without interrupting adjacent tap offs
  • Modbus RTU Output: Register map documented for BMS and DCIM integration out of the box
  • Local LCD Registers: Cumulative and resettable registers readable at the rack during fit out and audit
  • Mixed Outlet Configurations: C13, C19 and three phase outlets combined in one unit footprint

Applications

  • Colocation halls billing power per rack
  • AI data center GPU racks with per tenant power tracking
  • Facilities integrating rack power data into DCIM or BMS
  • Retrofit metering where panel level meters are not available

Technical Specifications

Rated Current16A / 32A / 63A per outlet
Outlets per Unit3, 6 or 12 outlet configurations
Metering AccuracyClass 1 per outlet, kWh and instantaneous kW
Metering OutputModbus RTU RS485, SNMP gateway option
DisplayLocal LCD per outlet, cumulative and resettable registers
Voltage220 / 380V AC, single and three phase outlets
ConnectionTool free plug in to busway, no interruption to adjacent units
EnclosureFlame retardant PC and steel, IP20
Metering StandardIEC 62053-21 class 1
Test StandardIEC 61439-6 / IEC 62053-21

Compliance and Testing

Metering accuracy is verified against IEC 62053-21 class 1 reference equipment, and each unit receives a factory calibration certificate with a documented Modbus register map.

Ordering Information

Specify outlet configuration, current per outlet, single or three phase arrangement, communication protocol and label wording for tenant identification.