| Brand Name: | ohory |
| Model Number: | OH-DCB-2N |
| MOQ: | 20 Meters |
| Price: | USD 105-290 / Meter |
| Packaging Details: | A and B paths crated separately with colour coded labels and paired joint kits |
| Payment Terms: | T/T, L/C at sight |
The OH-DCB-2N series supplies A and B power paths as a matched pair. Identical impedance keeps load sharing predictable, and physical separation with independent supports is maintained through every routing change so a fault or maintenance event on one path cannot affect the other. Separate test records for each path support concurrent maintainability audits.
| Rated Current per Path | 1250A - 4000A |
|---|---|
| Configuration | A and B paths, full 2N redundancy |
| Path Separation | Minimum 300mm physical separation, no shared hangers |
| Identification | Red and blue phase markers plus path labels at every joint |
| Isolation Verification | Continuity and insulation test per path, separate reports |
| Rated Insulation Voltage | 1000V AC |
| Rated Working Voltage | 690V AC |
| Tap Off | Dual input rack tap off with mechanical interlock option |
| Protection Degree | IP54 indoor |
| Test Standard | IEC 61439-6 / UL 857 |
Each path is insulation tested and continuity verified with its own report. Isolation distance is surveyed and documented at joint positions, and dual input tap off interlocks are function tested before shipment.
Provide per path current, redundancy tier, separation constraints from the layout, tap off quantity and interlock requirement.
| Brand Name: | ohory |
| Model Number: | OH-DCB-2N |
| MOQ: | 20 Meters |
| Price: | USD 105-290 / Meter |
| Packaging Details: | A and B paths crated separately with colour coded labels and paired joint kits |
| Payment Terms: | T/T, L/C at sight |
The OH-DCB-2N series supplies A and B power paths as a matched pair. Identical impedance keeps load sharing predictable, and physical separation with independent supports is maintained through every routing change so a fault or maintenance event on one path cannot affect the other. Separate test records for each path support concurrent maintainability audits.
| Rated Current per Path | 1250A - 4000A |
|---|---|
| Configuration | A and B paths, full 2N redundancy |
| Path Separation | Minimum 300mm physical separation, no shared hangers |
| Identification | Red and blue phase markers plus path labels at every joint |
| Isolation Verification | Continuity and insulation test per path, separate reports |
| Rated Insulation Voltage | 1000V AC |
| Rated Working Voltage | 690V AC |
| Tap Off | Dual input rack tap off with mechanical interlock option |
| Protection Degree | IP54 indoor |
| Test Standard | IEC 61439-6 / UL 857 |
Each path is insulation tested and continuity verified with its own report. Isolation distance is surveyed and documented at joint positions, and dual input tap off interlocks are function tested before shipment.
Provide per path current, redundancy tier, separation constraints from the layout, tap off quantity and interlock requirement.