Data Center Busway System
>
Dual Path A/B Redundant Busway System 1250A-4000A Physical Isolation for 2N Data Center Power Distribution

Dual Path A/B Redundant Busway System 1250A-4000A Physical Isolation for 2N Data Center Power Distribution

Brand Name: ohory
Model Number: OH-DCB-2N
MOQ: 20 Meters
Price: USD 105-290 / Meter
Packaging Details: A and B paths crated separately with colour coded labels and paired joint kits
Payment Terms: T/T, L/C at sight
Detail Information
Place of Origin:
Guangdong, China
Certification:
ISO 9001 / UL 857 / IEC 61439 / CNAS
Rated Current Per Path:
1250A - 4000A
Configuration:
A And B Paths, Full 2N Redundancy
Path Separation:
Minimum 300mm Physical Separation, No Shared Hangers
Identification:
Red And Blue Phase Markers Plus Path Labels At Every Joint
Isolation Verification:
Continuity And Insulation Test Per Path, Separate Reports
Rated Insulation Voltage:
1000V AC
Rated Working Voltage:
690V AC
Tap Off:
Dual Input Rack Tap Off With Mechanical Interlock Option
Protection Degree:
IP54 Indoor
Test Standard:
IEC 61439-6 / UL 857
Supply Ability:
16000 Meters per Month
Highlight:

Dual Path A/B Busway System

,

1250A-4000A Redundant Busway

,

2N Data Center Power Busway

Product Description

Dual Path A/B Redundant Busway System for 2N Distribution

The OH-DCB-2N series supplies A and B power paths as a matched pair. Identical impedance keeps load sharing predictable, and physical separation with independent supports is maintained through every routing change so a fault or maintenance event on one path cannot affect the other. Separate test records for each path support concurrent maintainability audits.

Key Features

  • Matched A/B Paths: Both paths produced as a pair from the same batch for identical impedance and load sharing
  • Verified Physical Isolation: No shared hangers or supports, minimum 300mm separation maintained through every routing change
  • Dual Input Rack Tap Off: Mechanical interlock option prevents paralleling of A and B sources at the rack
  • Separate Test Reports: Continuity and insulation records issued per path for concurrent maintainability audits
  • Colour Coded Identification: Path markers at every joint reduce misconnection risk during fit out

Applications

  • Tier III and Tier IV data centers with 2N distribution
  • AI data center rack rows fed from separate UPS systems
  • Facilities requiring concurrent maintainability certification
  • Colocation halls with SLA backed power path availability

Technical Specifications

Rated Current per Path1250A - 4000A
ConfigurationA and B paths, full 2N redundancy
Path SeparationMinimum 300mm physical separation, no shared hangers
IdentificationRed and blue phase markers plus path labels at every joint
Isolation VerificationContinuity and insulation test per path, separate reports
Rated Insulation Voltage1000V AC
Rated Working Voltage690V AC
Tap OffDual input rack tap off with mechanical interlock option
Protection DegreeIP54 indoor
Test StandardIEC 61439-6 / UL 857

Compliance and Testing

Each path is insulation tested and continuity verified with its own report. Isolation distance is surveyed and documented at joint positions, and dual input tap off interlocks are function tested before shipment.

Ordering Information

Provide per path current, redundancy tier, separation constraints from the layout, tap off quantity and interlock requirement.

Related Products

Good price  online

Products Details

Home > Products >
Data Center Busway System
>
Dual Path A/B Redundant Busway System 1250A-4000A Physical Isolation for 2N Data Center Power Distribution

Dual Path A/B Redundant Busway System 1250A-4000A Physical Isolation for 2N Data Center Power Distribution

Brand Name: ohory
Model Number: OH-DCB-2N
MOQ: 20 Meters
Price: USD 105-290 / Meter
Packaging Details: A and B paths crated separately with colour coded labels and paired joint kits
Payment Terms: T/T, L/C at sight
Detail Information
Place of Origin:
Guangdong, China
Brand Name:
ohory
Certification:
ISO 9001 / UL 857 / IEC 61439 / CNAS
Model Number:
OH-DCB-2N
Rated Current Per Path:
1250A - 4000A
Configuration:
A And B Paths, Full 2N Redundancy
Path Separation:
Minimum 300mm Physical Separation, No Shared Hangers
Identification:
Red And Blue Phase Markers Plus Path Labels At Every Joint
Isolation Verification:
Continuity And Insulation Test Per Path, Separate Reports
Rated Insulation Voltage:
1000V AC
Rated Working Voltage:
690V AC
Tap Off:
Dual Input Rack Tap Off With Mechanical Interlock Option
Protection Degree:
IP54 Indoor
Test Standard:
IEC 61439-6 / UL 857
Minimum Order Quantity:
20 Meters
Price:
USD 105-290 / Meter
Packaging Details:
A and B paths crated separately with colour coded labels and paired joint kits
Delivery Time:
18-28 working days after drawing approval
Payment Terms:
T/T, L/C at sight
Supply Ability:
16000 Meters per Month
Highlight:

Dual Path A/B Busway System

,

1250A-4000A Redundant Busway

,

2N Data Center Power Busway

Product Description

Dual Path A/B Redundant Busway System for 2N Distribution

The OH-DCB-2N series supplies A and B power paths as a matched pair. Identical impedance keeps load sharing predictable, and physical separation with independent supports is maintained through every routing change so a fault or maintenance event on one path cannot affect the other. Separate test records for each path support concurrent maintainability audits.

Key Features

  • Matched A/B Paths: Both paths produced as a pair from the same batch for identical impedance and load sharing
  • Verified Physical Isolation: No shared hangers or supports, minimum 300mm separation maintained through every routing change
  • Dual Input Rack Tap Off: Mechanical interlock option prevents paralleling of A and B sources at the rack
  • Separate Test Reports: Continuity and insulation records issued per path for concurrent maintainability audits
  • Colour Coded Identification: Path markers at every joint reduce misconnection risk during fit out

Applications

  • Tier III and Tier IV data centers with 2N distribution
  • AI data center rack rows fed from separate UPS systems
  • Facilities requiring concurrent maintainability certification
  • Colocation halls with SLA backed power path availability

Technical Specifications

Rated Current per Path1250A - 4000A
ConfigurationA and B paths, full 2N redundancy
Path SeparationMinimum 300mm physical separation, no shared hangers
IdentificationRed and blue phase markers plus path labels at every joint
Isolation VerificationContinuity and insulation test per path, separate reports
Rated Insulation Voltage1000V AC
Rated Working Voltage690V AC
Tap OffDual input rack tap off with mechanical interlock option
Protection DegreeIP54 indoor
Test StandardIEC 61439-6 / UL 857

Compliance and Testing

Each path is insulation tested and continuity verified with its own report. Isolation distance is surveyed and documented at joint positions, and dual input tap off interlocks are function tested before shipment.